- Home
- LL2 Digital Weight Indicator


Superior performance in all conditions, high weighing accuracy.
- EC Type Approval 10.000 d
- 6 Digits, 20 mm easily readable LED display
- High speed and accuracy
- RS232, RS422/485 Serial Data Ports
- X 10 View Function
Load-Line 2 weight indicator is especially designed with international high technology standards for floor scales, electronic truck scales and various types of industrial applications. Load Line 2 has high sensitivity owing to 100 times ADC conversion speed per second and 16.000.000 internal counting value. RS232, RS422/485 serial data outputs are standard in Load line 2. Also, it can be connect personal computers, remote displays and printers. As result of additional analog or digital output options, it can be integrated to automation systems.
It works robustly even in dusty and moist enviroments owing to its industrial design. Load Line 2 has table, colon, and panel and ex-proof models for hazardous areas. It can be used on colon or table and can be mounted on a wall or panel with respect to application type.
Easy to Use
Load Line 2 provides easy and quick programming and usage opportunitieswith the user-friendly and block structure menu,
High speed and accuracy
With 100 times ADC conversion speed per second and 24 bit 16,000,000 internal counting value, Load Line 2 provides more rapid and accurate weihging.
Weighing range selection
Single and multi range weighing selection function on demand
Anti-Wibration Filter
With programmable digital and sudden load filter levels, it saves weighing from enviormental factors (vibration, noise) and harmful effects of hitting loads. It allows accurate and reliable weighing for the applications like dynamic weighing
Self Calibration
Electronic calibration without requiring any load for industrial applications
Serial Communication
Standard RS232 C serial data output provides 300 – 9600 baud rate, 8 data bits, 1 start bit, 1 stop bit and none parity protocol serial communication.
Also with standard RS 422/485 serial output, it allows Half-Full Dublex communication or optional MODBUS R TU communication over RS 232 / RS 422/485.
Control Inputs / Outputs
Free programmable optional 4 I/O input-output card. Optoisolated 5 V DC (PNPlogic) input, TTL, 1 A/24 V DC or 0.5 A / 125 V AC relay output option
Analog Output
0-20 mA / 4-20 mA or 0-10 V analog output option allows communication for automation systems like PLC , and other devices.
Alibi Memory
Optional, alibi memory allows storing 105.000 records including weighing number, gross , tare and net weight information.
Printer Connection/Labeling
Trough RS232 data output connection Load L line 2 can print ticket, stick label and barcode by connecting thermal, ribbon, dot matrix and barcode type printers In weighing ticket, ticket number, date -time, gross , tare, net and company Name with Turkish-English Language option can be printed . Ticket- label desing , language settings and the information which will be printed to ticket can be desinged by the operator.
Software
Load line 2 provides giving possibility to flexible programming for developing special applications for non-trade metrological applications by using additional devices and equipments.
Additional Functions
Simple piece counting, peak hold, dynamic weighing, automatic filling and tolerance control mode operation options.
Properties of standard | |
---|---|
Accuray Class | III / IIII |
Aprroved Division | 10.000 d Single and Multi Interval |
Certificates | 2009/23 EC, OIML R76, CE |
Display | 6 Digits, 20 mm. Led Display |
Status Indicators | Stand still, Zero, Net, Weight Range, Pcs, Lb and Kg symbols |
Key pad | Membran type, 8 functional Touch sense keys |
A/D Converter / Speed | 24 Bit Delta-Sigma – 10 ms. – 6.25-100 Hz. |
Signal Range | 0,1mvV/V- 3mV/V |
Input Voltage | 0.83 µV/e |
Internal Resulation / Division | 1/16.000.000 Internal Conversions / Display up to 80.000 |
Linearity & Temp Co-efficient | % 0.0015 FS; ≤ 2 ppm / ºC |
Loadcell Excitation | 5 V DC |
Loadcell Connection | Min. 1 unit 43,75 ohm, / Max. 8 units 350 ohm, 25 units 1100 ohm |
Serial Communication | RS 232 / 485 |
Power Supply | 12 VDC / 5 W (max.) |
Operation Temperature | -10°….+ 40°C / %85 RH |
Protection Class | IP 54 / IP 65 |
Housing | Aluminium Cast (Standard) / Stainless Steel (Option) |
Model | Size – Weight | Size With Package – Weight |
---|---|---|
LL2 CTB | 168x162x99 mm – 2 kg | 330x210x120 mm – 2,8 kg |
LL2 CTD | 215x154x158 mm – 1,5 kg | 330x210x120 mm – 2,3 kg |
LL2 POA | 168x162x99 mm – 1,5 kg | 330x210x120 mm – 2,3 kg |
LL2 Ex-Proof | 241x172x302 mm – 13,8 kg | 390X310X240 mm – 14,9 kg |
Opsiyonlar | |
---|---|
Serial Communication | 2 x RS232, 1 x RS422 / 485 (Half-Full Dublex), MODBUS RTU , Ethernet, TCP / IP |
Wireless Communication | RF |
Analog Output | 0-10 V / 0-20mA / 4-20 mA |
Digital Input/Output | Optoizolated 4 inputs (5 VDC-PNP Logic-) / 4 TTL, 1 A/24 VDC or 0.5 A/125 VAC relay outputs |
Alibi Memory | 2MB. (105.000 Records) |